
USSC 1851772 rev ACSSUCOMPANYUNITED STATES STOVEUnited States Stove Company • 227 Industrial Park Road, P.O. Box 151 • South Pittsburg, TN 37380 • ww
10 USSCGUIDELINES FOR EXHAUST VENTING SYSTEMS DESIGNIt is recommended that only an authorized installer install your multi-fuel heater, preferably an
USSC 111. For installations with horizontal through-the-wall exhaust, it is strongly recommended that the heater combustion air be connected to the
12 USSCThe Multifuel Heater Model 6041TP/6041HF may be installed as follows: 1) A freestanding unitThe Multifuel Heater Model 6041I insert may be in
USSC 1311223344A AB B12 1/811 3/410 1/16EXHAUST OULET3" DIA.COMBUSTIONAIR INTAKE1 7/8" DIA.10 1/1611 5/812EXHAUST OUTLET3' DIACOMBUSTI
14 USSCTHROUGH THE WALL, VERTICAL PIPE INSTALLATIONWITH TERMINATION CAPThe Hearth Pad is not required under the unit if the oor is noncombustible bu
USSC 15DESIGN GUIDELINES FOR 6041I INSERT INSTALLATIONINSTALLATION AS A BUILT-IN FIREPLACEA continuous sheet of non-combustible oor protection must
16 USSCDESIGN GUIDELINES FOR 6041I INSERT INSTALLATIONINSTALLATION INTO A MASONRY FIREPLACEWhen installing into a masonry replace, DO NOT remove any
USSC 17Your Multi-Fuel Heater comes to you with the glass door installed in place, ready for use. The glass is surrounded on the edges with a gasket
18 USSCUNDERSTANDING THE CONTROL BOARDCONTROL PANELTurning the heater OFF/ON, as well as adjustments for the fuel feed rate and room fan speed are pe
USSC 19• Fill the burnpot with wood pellets up to the level of the igniter port; See illustration. • Close all doors, lids, and cleanouts.• Press
2 USSC NOTE: YOUR UNIT MUST BE INSTALLED BY A QUALIFIED INSTALLER, such as an NFI (National Fireplace Institute) Certied SpecialistYou’ve purchased
20 USSCSoot and Flyash - Formation and Need for RemovalThe products of combustion will contain small particles of yash. The yash will collect in t
USSC 21WARNINGThese automatic safety features must not be bypassedWeekly Maintenance• Shut down the heater as directed in the operating instructions
22 USSCCONTROL BOARD FUNCTIONSSTART-UP SEQUENCE OF EVENTSOnce the control panel is turned on, a timer begins that will start, stop and continue opera
USSC 23Display IndicatorsSeveral situations or events are indicated in normal operation by blinking display indicators or segments in the display:Fla
24 USSCTROUBLE SHOOTINGPROBLEM CAUSE: Too rich air/fuel mixtureOrange, lazy ame, excessive fuel build-up in the burnpot.• Clean out the burnpot• M
USSC 25WIRING DIAGRAMWIRING SCHEMATIC
26 USSCPARTS DIAGRAM - 6041TP632930686639383432312223242625595860363537331240414846454342282765645761625644475455495251505332120171819111013127269141
USSC 27PARTS LIST - 6041TP1 69529 Pedestal 12 25410 Pedestal Bottom 13 25451 Pedestal Back 14 69478 Ash Pan 15 891137 Handle 16 25533 Damper/Cleanout
28 USSCPARTS DIAGRAM - 6041I2122192023242526171676346511102981014131512182212728
USSC 29PARTS LIST - 6041IParts ListKey Part No. Description Qty. Key Part No. Description Qty.1 891373 Pad, Door Hinge (Threaded) 2 17 25580 Left Sid
USSC 31122A AB BAssembly1. Unpack unit and make sure all components are included; (4) Legs, and all hardware for installation.2. Fold the corner padd
30 USSCPARTS DIAGRAM/LIST431567298101111223344A AB B1 86623LOUVER32 83531SCREW, STAINLESS23 83532SPACER4483530 HEX NUT, STAINLESS 2525444 LOUVER BRAC
USSC 31NOTE
32 USSCThis manual will help you obtain efcient, dependable service from the furnace, and enable you to order repair parts correctly.Keep this manua
4 USSC(a)(a)(c)(h)(f)(g)(b)(e)6041I ASSEMBLY(i)(j)For the following assemblies, we suggest locating the unit near it’s desired location. Dep
USSC 5COMPONENT LOCATION
6 USSCAshes will have to be removed from the heater for proper operation. See cleaning procedure.Your Multi-fuel heater, due to the nature of solid
USSC 7FLOOR PROTECTIONThe Multifuel Heater may be installed on a combustible oor, with proper oor protection, or on a masonry hearth. The hearth o
8 USSCCLEARANCES TO COMBUSTIBLES 6041(TP)(HF)The heater must be installed with the following minimum clearances to side and back wall combustible mat
USSC 9CLEARANCES TO COMBUSTIBLES 6041I
Commenti su questo manuale